Home  >  Products  >  End Suction Pump  >  SCW End Suction Pump

SCW End Suction Pump

FILIPUSI SCW series long-coupled back pull-out end suction centrifugal pump with spacer coupling and frame-mounted baseplate


 

SCW Series Long-Coupled Back Pull-Out End Suction Pump

Frame-Mounted Design | Spacer Coupling | Back Pull-Out Maintenance | Heavy-Duty Industrial Process

The FILIPUSI SCW Series is a heavy-duty, frame-mounted end suction centrifugal pump featuring a long-coupled spacer coupling design that enables complete rotating assembly removal for maintenance without disconnecting suction or discharge piping — or even moving the motor. Engineered for critical-process applications where uptime and maintainability are paramount, the SCW series delivers flows from 12.5 to 400 m³/h and heads up to 125 meters. Available in cast iron, AISI 304/316 stainless steel, Duplex 2205, and bronze constructions for chemical process, boiler feed, power generation, and heavy-duty industrial fluid transfer worldwide.

REQUEST SCW PUMP QUOTE » DOWNLOAD SCW CATALOG (PDF)

Why Choose SCW Long-Coupled End Suction Pumps?

Back Pull-Out Maintenance

The complete rotating assembly — impeller, shaft, bearings, and mechanical seal — can be extracted through the rear of the pump without disconnecting suction or discharge piping. This eliminates the need for pipe re-alignment and reduces maintenance downtime by up to 70% compared to non-back-pull-out designs.

Spacer Coupling Design

A precision-machined spacer coupling connects the motor shaft to the pump shaft. For mechanical seal replacement, technicians simply remove the spacer coupling element and extract the seal cartridge through the gap — without moving the motor or breaking pipe flanges. Seal replacement can be completed in under one hour.

Heavy-Duty Frame-Mounted Baseplate

The pump and motor are pre-aligned on a rigid steel or cast iron baseplate, ensuring permanent shaft alignment and minimizing vibration. The frame-mounted design supports larger motor sizes (up to 160 kW) and provides stable operation for continuous 24/7 critical-process duty.

SCW Long-Coupled vs. FS Close-Coupled — Which Design Do You Need?

Feature SCW Long-Coupled FS Close-Coupled
Seal replacement without moving motor Yes (spacer coupling) No (motor must be removed)
Back pull-out rotating assembly Yes No
Pipe disconnection for maintenance Not required Required
Maximum motor power Up to 160 kW Up to 55 kW
Footprint Larger (baseplate) Compact (30% smaller)
Ideal for Critical process, large pumps, frequent maintenance Space-limited, standard duty, occasional maintenance

Working Principle & Structural Engineering

Driven by an electric motor through a precision spacer coupling, the pump shaft rotates the closed impeller to draw fluid horizontally along the axial suction centerline. Centrifugal acceleration propels the liquid outward into the volute casing, converting kinetic velocity into steady discharge pressure. The long-coupled frame-mounted design isolates motor vibration from the pump hydraulic assembly, ensuring smooth, low-vibration operation even at high flow rates and continuous 24/7 duty cycles.

Back Pull-Out Rotating Assembly: The entire rotating element — impeller, shaft, bearing housing, and mechanical seal — is designed to slide out through the rear of the casing as a single cartridge. No pipe disconnection, no motor removal, no re-alignment required.
Spacer Coupling for Quick Seal Access: A removable spacer element between the motor coupling hub and pump coupling hub creates a maintenance gap. Remove the spacer, slide the seal cartridge out, replace, and re-install — all without moving the motor or breaking pipe flanges.
Heavy-Duty Bearing Housing: Grease-lubricated heavy-duty ball bearings (or oil-lubricated sleeve bearings on large models) support the pump shaft independently of the motor. This isolates hydraulic thrust loads from the motor bearings, extending motor service life and allowing independent bearing replacement.
Rigid Baseplate with Permanent Alignment: Pump and motor are factory-aligned on a rigid steel or cast iron baseplate with machined mounting surfaces. Once installed, shaft alignment remains permanent — no routine re-alignment needed, reducing maintenance costs over the pump lifecycle.
Versatile Material & Seal Options: Casings in cast iron (standard), AISI 304/316L stainless steel, Duplex 2205, or bronze. Mechanical seals from NS-24/B1SE4 (standard) to double cartridge seals with API flush plans (Plan 11/21/32/53A) for hazardous and high-temperature process fluids.

Performance Curves & Hydraulic Range

SCW series long-coupled end suction pump performance curve - flow rate vs head, efficiency, NPSHr, and power consumption at 1480rpm


 
SCW series long-coupled end suction pump dimensional drawing - overall dimensions, flange drillings, baseplate mounting holes, and spacer coupling gap


SCW series covers 1480/2900 rpm (50Hz) / 3500 rpm (60Hz).
Contact our engineers for full performance curves, NPSHr data, and dimensional drawings for your specific model.

SCW Technical Specifications & Engineering Data

Engineering Parameter
Standard Range
Custom Options & Upgrades
Flow Rate (Q)
6.3 – 1600 m³/h
Custom impeller trimming for exact BEP duty points
Discharge Head (H)
Up to 165 meters (16.5 bar)
Reinforced casing for high-pressure service up to 20 bar
Motor Power Range
0.75 kW – 200 kW
IE2/IE3/IE4 premium efficiency, explosion-proof (ExdIIBT4)
Rotational Speed
2900 rpm (50Hz) / 3500 rpm (60Hz)
1450 rpm (50Hz) / 1750 rpm (60Hz) for large low-speed models
Inlet / Outlet Size
DN32 – DN350
DIN / ANSI / JIS flange standards; PN16/PN25 ratings
Casing Material
Cast Iron (electrophoretic coating, standard)
AISI 304 / 316L SS, Duplex 2205, Bronze, CD4MCu, Hastelloy
Impeller Material
Cast Iron / Bronze (standard)
AISI 304/316 SS, Duplex 2205, Ni-Al Bronze
Mechanical Seal
NS-24 / B1SE4 (silicon carbide faces, standard)
Double cartridge seals, API flush plans (Plan 11/21/32/53A), tandem seals
Bearing Type
Grease-lubricated heavy-duty ball bearings
Oil-lubricated sleeve bearings (large models), forced lubrication
Coupling Type
Spacer coupling (flexible, with removable spacer element)
Gear coupling, grid coupling, torque-limiting coupling
Baseplate
Steel fabricated baseplate (standard)
Cast iron baseplate, grouted base, common baseplate with motor
Fluid Temperature
-20°C to +120°C (standard)
Up to +250°C with cooling jacket and high-temp seals
Pressure Rating
PN16 (16 bar)
PN25 / PN40 high-pressure casings
Power Supply
380V / 50Hz, 3-phase (Standard IP55)
220V /380V/ 415V / 440V / 460V, 50/60Hz, VFD-ready
Standards & Certifications
CE, ISO 9001:2015, ISO 2858 dimensions
ANSI B73.1, API 610, CCS/ABS/DNV marine, ATEX
FILIPUSI SCW Long Shaft End Suction Pump Part Cross-Sectional View

Key Applications & Industry Use Cases

Chemical & Petrochemical Process

Transfer of corrosive chemicals, solvents, acids, and process fluids in refineries, chemical plants, and petrochemical facilities. The back pull-out design allows safe maintenance of hazardous fluid pumps without breaking containment, and double mechanical seals with API flush plans prevent leakage. AISI 316L, Duplex 2205, and Hastelloy constructions available for aggressive media.

Boiler Feed & Power Generation

Feedwater supply for steam boilers, hot water heating systems, and cogeneration plants in power stations, hospitals, and industrial facilities. High-temperature mechanical seals and cooling jackets allow operation with fluid temperatures up to 250°C. The long-coupled design handles high inlet pressures typical of deaerator and boiler feed applications.

Industrial Process Cooling & Chillers

Chilled water circulation for process cooling, induction furnace cooling, die-cast thermal regulation, and large-scale chiller plants in manufacturing and data centers. The frame-mounted design supports continuous 24/7 operation with minimal vibration, and the back pull-out feature enables maintenance during scheduled shutdowns without draining the entire cooling system.

Water Treatment & Reverse Osmosis

High-pressure feed for reverse osmosis (RO) systems, ultrafiltration, deionized water loops, and municipal water treatment plants. All-stainless-steel wetted paths (AISI 304/316L) ensure clean, contamination-free fluid transfer for pharmaceutical and food-grade water treatment. VFD-compatible motors enable precise pressure control for membrane protection.

Marine & Offshore

Seawater cooling, ballast water transfer, firefighting systems, and general service water on commercial ships, offshore platforms, and FPSO units. Bronze and Duplex stainless steel constructions resist chloride pitting and corrosion. CCS/ABS/DNV certification available for classified vessel installations, and explosion-proof motors for hazardous area zones.

HVAC & District Energy

Large-scale chilled and hot water circulation for district heating/cooling networks, high-rise commercial buildings, airports, universities, and hospital campuses. The long-coupled design is preferred for large pumps (above 55 kW) where maintainability and extended bearing life are critical. IE3/IE4 motors and VFD control deliver energy efficiency for variable-load HVAC systems.

How to Select the Right SCW Long-Coupled Pump

Selecting the optimal SCW long-coupled pump requires matching hydraulic performance to system requirements, with special attention to maintainability and total cost of ownership for critical-process applications:

01 Hydraulic Performance (Flow & Head): Determine the required flow rate (Q) and total dynamic head (TDH) including static elevation, friction loss, and terminal pressure. The SCW series covers 12.5 to 400 m³/h and heads up to 125m. Select a pump operating at or near its Best Efficiency Point (BEP) — operation below 50% or above 120% of BEP causes excessive vibration, cavitation, and premature seal/bearing failure.
02 Fluid Properties & Material Selection: Standard cast iron construction suits clean water and non-corrosive fluids up to 80°C. For corrosive chemicals, specify AISI 316L or Duplex 2205 stainless steel. For seawater, specify Ni-Al Bronze or Duplex 2205. For high-purity pharmaceutical/food applications, specify AISI 316L with electropolished wetted surfaces. For fluids above 120°C, specify high-temperature mechanical seals with cooling jacket (Plan 21 or Plan 32).
03 Seal Selection for Process Safety: Standard NS-24/B1SE4 single mechanical seals are suitable for non-hazardous, non-toxic fluids. For hazardous, toxic, or expensive process fluids where leakage is unacceptable, specify double mechanical seals with API flush plans: Plan 11 (internal recirculation) for clean fluids; Plan 21 (cooling bypass) for high-temperature fluids; Plan 32 (external flush) for abrasive or polymerizing fluids; Plan 53A (barrier fluid) for zero-emission hazardous service.
04 Long-Coupled vs. Close-Coupled Decision: Choose the SCW long-coupled design when: (a) motor power exceeds 55 kW; (b) the application is critical-process where uptime is paramount; (c) frequent seal/bearing maintenance is expected; (d) the fluid is hazardous and maintenance must avoid pipe disconnection; (e) independent bearing housing is required for high-thrust loads. Choose the FS close-coupled series for space-limited installations, smaller motors (under 55 kW), and standard-duty applications where frequent maintenance is not expected.

Free engineering & selection service: FILIPUSI application engineers provide complimentary pump selection, seal plan recommendation, and material compatibility analysis. Send us your required flow, head, fluid properties (chemical name, concentration, temperature, viscosity), NPSHa, and voltage, and we will recommend the optimal SCW model with full performance curve, dimensional drawing, and seal plan specification within 24 hours.

SCW Long-Coupled Pumps - Frequently Asked Questions

Q1: What is the main advantage of a long-coupled (frame-mounted) pump over a close-coupled pump?

A1: The primary advantage is maintainability. In a long-coupled pump, the motor is connected to the pump shaft through a spacer coupling on a common baseplate. For mechanical seal replacement or bearing service, technicians remove the spacer coupling element and extract the rotating assembly through the rear — without moving the motor, disconnecting piping, or re-aligning the shaft. This reduces maintenance downtime by up to 70% and eliminates the risk of misalignment after service. Close-coupled pumps require full motor removal and pipe disconnection for seal service.

Q2: Can the SCW series replace my existing ISO 2858 or ANSI B73.1 end suction pump directly?

A2: Yes. The SCW series is designed to ISO 2858 (EN 733) dimensional standards as standard, with ANSI B73.1 compliant options available. This means the flange-to-flange dimensions, shaft height, and baseplate mounting holes match standard ISO/ANSI pumps, allowing direct drop-in replacement without pipe modification or baseplate re-drilling. However, because the long-coupled design includes a baseplate and motor, verify that the overall footprint (including motor overhang) fits your existing installation space.

Q3: How long does it take to replace a mechanical seal on a long-coupled pump?

A3: With the spacer coupling design, a trained technician can replace a mechanical seal in 30-60 minutes — compared to 3-6 hours for a close-coupled pump (which requires motor removal, pipe disconnection, and re-alignment). The procedure is: (1) isolate and drain the pump; (2) remove the spacer coupling element; (3) unbolt the seal chamber cover; (4) slide out the old seal cartridge; (5) install the new seal; (6) re-assemble. No motor movement or pipe flange breaking is required.

Q4: What bearing and lubrication options are available for the SCW series?

A4: Standard SCW pumps use grease-lubricated heavy-duty deep-groove ball bearings in an independent bearing housing, isolated from the motor bearings. For larger models (above 75 kW) or high-thrust applications, oil-lubricated sleeve bearings or angular contact thrust bearings are available. For continuous 24/7 critical service, forced lubrication systems with oil coolers and filters can be provided. Bearing life is typically 40,000-60,000 hours (L10) for clean water service at rated load.

Q5: Can the SCW series handle hazardous or flammable fluids?

A5: Yes. For hazardous or flammable fluid applications, specify: (a) double mechanical seals with API Plan 53A (pressurized barrier fluid) for zero-emission containment; (b) explosion-proof motors (ExdIIBT4 or ExdIICT4) rated for the hazardous area zone; (c) conductive or anti-static gasket materials; (d) ATEX-compliant construction if required for EU installations. For toxic or carcinogenic fluids, tandem seals with leakage detection are recommended. All hazardous-service configurations are factory-tested before shipment.

Q6: What is the recommended maintenance schedule for SCW long-coupled pumps?

A6: For normal clean water service: inspect for leaks, unusual noise, and vibration monthly; check bearing temperature and lubrication every 3 months; replace mechanical seal every 12,000-16,000 hours (or every 2 years for continuous 24/7 operation); inspect bearings and re-grease every 18,000-24,000 hours; inspect impeller and wear ring for corrosion/erosion every 24,000-32,000 hours. For corrosive or abrasive fluid service, reduce all intervals by 50%. The back pull-out design allows all maintenance tasks without pipe disconnection, significantly reducing maintenance labor cost. FILIPUSI supplies OEM spare part kits including seals, bearings, impellers, wear rings, and gaskets for all SCW models.

Need a Heavy-Duty Long-Coupled Pump for Critical Process?

FILIPUSI provides full OEM/ODM engineering for SCW long-coupled pumps — including custom material selection, API seal plan configuration, baseplate design, and complete skid-mounted packages. Get a free pump selection, performance curve, and dimensional drawing within 24 hours.

Industrial Centrifugal Pump Manufacturer & Exporter | www.filipusi.com

Related Pump Series & Categories

FS Close-Coupled Series

General-purpose ISO 2858 end suction pump with motor directly mounted to pump bracket. Compact footprint, 30% smaller than long-coupled. Ideal for space-limited installations and motors under 55 kW.

View FS Series »

SW High-Efficiency Series

CFD-optimized high-efficiency end suction pump with IE3/IE4 motors. Saves 10-20% energy vs standard pumps. Ideal for energy-conscious HVAC, municipal boosting, and continuous-duty applications.

View SW Series »

VS Multistage Series

Vertical inline multistage pumps for heads above 125m. All-stainless-steel construction, compact footprint, up to 350m discharge head. Ideal for high-pressure water boosting, boiler feed, and RO systems.

View VS Multistage »

Other categories: Vertical Inline Centrifugal Pumps | Double Suction Split Case Pumps | Marine & Shipboard Pumps

Product Number Product model Flow Head Motor power Voltage Frequency(f) Inlet diameter Outlet diameter Material Mechanical seal sealing Weight(kg)
SCW32-125-0.75 SCW32-125-0.75 12.5(m³/h) 12(m) 0.75KW 380V 50HZ DN32 DN32 Cast iron (electrophoretic treatment) NS-24/B1SE4 64KG
Total1Previous1Total 1 pages
 

CONTACT US

Copyright 2026 © Filipusi (Zhejiang) Water Affairs Co., Ltd. All Rights Reserved.