Home  >  Products  >  Double Suction Split Case Pump

Double Suction Split Case Pump

Double Suction Split Case Pump Manufacturer in Zhejiang, China

FILIPUSI builds double suction split case pumps in horizontal and vertical layouts at its Yongjia works in Wenzhou, and ships them to water utilities, power stations, cooling-water systems, irrigation districts and process plants. The published range runs from 66 to 30,000 m³/h, with total heads from 6 to 280 m.

A double suction impeller takes water through both eyes, so axial thrust is largely balanced inside the casing. The casing itself is split along the shaft axis: lift the upper half and the rotor, wear rings and seal are in front of you, with the suction and discharge pipes still connected. That is what makes this pump type the standard choice for high-flow duties that have to run for years between overhauls.

FILIPUSI horizontal double suction split case centrifugal pump, cast iron body, high flow industrial water pump

CW series horizontal double suction split case pump, cast iron body

Published Range at a Glance

FILIPUSI double suction split case pump series
Flow rate 66–30,000 m³/h
Total head 6–280 m
Motor power 11–2,500 kW
Nominal size DN150–DN1600 on the horizontal CW series; vertical nozzle sizes from the model drawing
Liquid temperature -20 °C to +120 °C
Casing pressure PN10 / PN16 standard; PN25 and PN40 available by model
Flange standards DIN, ANSI or JIS on request
Factory testing Hydrostatic casing test, performance run, dynamic shaft balancing, inspection record with the shipment

Horizontal or Vertical — Which Layout Fits the Pump Room

Both layouts use the same double suction hydraulic end. What changes is how the unit sits in the building, how much room the rotor needs for service, and how the suction piping is arranged. The cutaway below is the horizontal arrangement — pump body, coupling guard, motor and baseplate in one frame. Compare the two layouts in the table, then open the series page for models and drawings.

Cutaway view of a horizontal double suction split case pump showing pump casing, coupling guard, motor and baseplate

Horizontal arrangement: split casing, coupling guard, motor and baseplate

  Horizontal, CW series Vertical arrangement
How it sits Baseplate bolted to a concrete foundation, shaft between two bearing housings, motor on a common base. Motor mounted above the pump; the shaft runs vertically down to the impeller.
Floor space More floor area, but only modest headroom needed over the casing. Smaller floor footprint; the pump room has to give clearance above the motor for lifting.
Service access Upper casing half lifts off; rotor removed with a light crane over the unit. Motor and coupling come off first, then the rotor is lifted out vertically.
Usually specified for Power station cooling water, utility raw and treated water transfer, large irrigation and drainage stations. Compact or underground stations, capacity upgrades inside an existing building, sites where the civil work cannot be enlarged.
Range 66–30,000 m³/h, 6–280 mHorizontal double suction split case pump » 80–12,000 m³/h, 5–220 mVertical double suction split case pump »

Materials for Fresh Water, Cooling Circuits and Sea Water

The wetted material set is the part of the specification buyers most often get wrong, and it is the part that decides whether the pump survives its first ten years. FILIPUSI builds the same hydraulic end in several material combinations. The table below is the usual starting point; the final choice follows a water analysis and the chloride level at operating temperature.

Duty Typical build Watch for
Treated water, closed cooling loop Cast iron casing, bronze impeller, carbon steel shaft Water treatment chemistry, inhibitor dosing
River, reservoir, raw water intake Cast iron or cast steel, bronze or SS304 impeller Sand and silt in the suction line, screen losses
Brackish water, estuary intake SS316 or duplex 2205 wetted parts Chloride level, pitting risk at the wear ring gap
Sea water, cooling and ballast Nickel-aluminium bronze or super duplex 2507, shaft sleeved Velocity, crevice corrosion, seal plan
Hot water above 80 °C Cast steel, high-temperature seal and gasket set Thermal growth at the coupling, seal flush

Nickel-aluminium bronze impeller for a double suction split case pump on sea water duty

Nickel-aluminium bronze impeller, the build used for sea water and brackish cooling duty

Sea water versions are also listed separately on the marine double suction pump page, which covers shipboard cooling and ballast duty.

Where Double Suction Split Case Pumps Are Used

Duty What the pump is doing
Power plant cooling water Circulating condenser cooling water, continuous duty, high flow at moderate head.
Municipal supply and raw water Intake from river or reservoir, transfer to treatment works, clear-water pumping into distribution.
Industrial cooling and process water Steel mills, refineries, chemical plants; closed or once-through circuits.
District energy and large HVAC Chilled and heating water circulation for campuses, airports, data centres and district networks.
Irrigation and drainage Large-volume transfer, pumping stations, flood control.
Fire water and treatment backwash Dedicated fire-water supply and filter backwash duty where the flow falls inside the range.

Double suction split case pump set installed at a power station cooling water pump house

Split case pump on power station circulating water duty

Horizontal double suction split case pump set running in an industrial pump room

Horizontal set in an industrial pump room, motor on a common baseplate

What to Send Us for a Selection

Six numbers and one drawing are enough to put a model on the table. Send them together and the reply comes back with a duty point, a curve and a dimensional drawing, not a request for more information.

Send Why it decides the model
Flow, m³/h — normal, minimum, maximum Minimum flow sets the smallest casing that will not run into recirculation; maximum flow sets the impeller trim.
Total head, m Static lift plus friction, valve and exchanger losses, plus the pressure needed at the outlet.
Suction condition and NPSHa Water level range, suction pipe layout and losses decide whether the impeller runs clear of cavitation.
Liquid, temperature, chloride Fixes the wetted material set and the seal arrangement.
Power supply Voltage, frequency and starting method fix the motor and whether a VFD is quoted.
Pump room drawing or site dimensions Decides horizontal or vertical, flange orientation and how the rotor will be lifted for service.

Testing, Documentation and Lead Time

Every unit is hydrostatically tested at the casing, run against its duty point on the test bed, and the shaft is dynamically balanced before assembly. Test records go out with the pump. Material certificates to EN 10204 3.1 and witness inspection can be added to the order when the project calls for them.

Standard cast iron and cast steel builds run 15–25 working days. Stainless, bronze and duplex builds run 30–45 working days, set by the casting schedule for the specific material. Third-party inspection and special test requirements are added to that window, so the delivery date is confirmed against the final purchase order rather than assumed from the catalogue.

Double Suction Split Case Pump — Questions Buyers Ask

How does a double suction split case pump differ from an end suction pump?
The impeller is fed from both sides and the casing splits horizontally. Flow per unit is higher, axial thrust is balanced inside the pump instead of being carried by the bearings, and the rotor can be reached from above. An end suction pump is smaller and cheaper at low and medium flow. The crossover sits at the duty point, not at a fixed flow figure — compare the curves at your actual head.

What flow and head can the FILIPUSI range cover?
66–30,000 m³/h and 6–280 m total head as published. Individual models cover a slice of that envelope; the duty point, not the envelope, decides which model is quoted.

Can the same pump run on sea water?
Yes, with the right wetted set — nickel-aluminium bronze, SS316, duplex 2205 or super duplex 2507 depending on chloride level and temperature — and with a seal plan written for the application. Send the water analysis with the enquiry.

Horizontal or vertical for a tight pump room?
Vertical, in most cases. The floor footprint drops and the unit fits where the civil structure cannot be extended. Check headroom for motor removal before fixing the layout; that clearance is the usual constraint on a vertical installation.

Do you supply the bare pump or a complete set?
Both. A set normally means pump, baseplate, coupling and guard, motor, mechanical seal and the terminal box arrangement agreed on the drawing. Spare wear rings, sleeves and seal parts can be added to the same order.

How long from order to shipment?
15–25 working days for standard cast iron and cast steel, 30–45 working days for stainless, bronze and duplex material sets.

Need a Model and a Price for Your Duty?

Send flow, head, liquid, temperature, suction condition, power supply and quantity. You get the model, the curve, the drawing and the price in one reply.

SEND YOUR DUTY POINT »    DOWNLOAD THE CATALOG (PDF) »

Selection Guides and Related Ranges

How to size a high-flow double suction pump
Horizontal vs vertical split case pumps — layout and selection
Double suction pump working principle and maintenance
Choosing corrosion-resistant materials for industrial pumps

Other ranges: end suction pumps | multistage pumps | vertical inline pumps | marine and sea water pumps | fire pumps

 

CONTACT US

Copyright 2026 © Filipusi (Zhejiang) Water Affairs Co., Ltd. All Rights Reserved.